Back to HomeBeta

ICD-10 Coding for Biophysical Profile 4/8(O28.8)

Complete ICD-10-CM coding and documentation guide for Biophysical Profile 4/8. Includes clinical validation requirements, documentation requirements, and coding pitfalls.

Also known as:

BPP 4/8Abnormal Biophysical Profile

Related ICD-10 Code Ranges

Complete code families applicable to Biophysical Profile 4/8

O28-O36Primary Range

Maternal care related to the fetus and amniotic cavity and possible delivery problems

This range includes codes for abnormal findings on antenatal screening and specific fetal conditions.

Key Information: ICD-10 code for biophysical profile 4/8

Essential facts and insights about Biophysical Profile 4/8

The ICD-10 code for a biophysical profile score of 4/8 is O28.8, used for abnormal findings on antenatal screening.

Primary ICD-10-CM Code for biophysical profile 4/8

Other abnormal findings on antenatal screening of mother
Billable Code

Decision Criteria

clinical Criteria

  • BPP score of 4/8 with specific abnormal findings

documentation Criteria

  • Detailed documentation of each BPP component

Applicable To

  • Abnormal biophysical profile

Excludes

  • Normal antenatal screening (Z34.-)

Clinical Validation Requirements

  • BPP score of 4/8
  • Absence of fetal breathing movements for ≥30 seconds
  • Amniotic fluid index ≤5 cm

Code-Specific Risks

  • Incorrectly coding as normal screening
  • Failure to document specific abnormal findings

Coding Notes

  • Ensure documentation specifies each component of the BPP and any additional findings.

Ancillary Codes

Additional codes that should be used in conjunction with the main diagnosis codes when applicable.

Other specified disorders of amniotic fluid and membranes

O41.8-
Use when there is oligohydramnios or other specified amniotic fluid disorders.

Differential Codes

Alternative codes to consider when ruling out similar conditions to the primary diagnosis.

Maternal care for abnormalities in fetal heart rate or rhythm

O36.83-
Use when there is a specific abnormality in fetal heart rate or rhythm.

Documentation & Coding Risks

Avoid these common documentation and coding issues when documenting Biophysical Profile 4/8 to ensure proper reimbursement, maintain compliance, and reduce audit risk. These guidelines are particularly important when using ICD-10 code O28.8.

Impact

Clinical: Potential misinterpretation of fetal health status., Regulatory: Non-compliance with documentation standards., Financial: Risk of claim denials due to insufficient documentation.

Mitigation Strategy

Use structured templates for BPP documentation., Ensure all components are scored and documented.

Impact

Reimbursement: Incorrect billing could lead to denials., Compliance: Non-compliance with coding guidelines., Data Quality: Inaccurate data on fetal assessments.

Mitigation Strategy

Use CPT 76819 with 59025 for separate NST billing.

Impact

Incomplete or inaccurate documentation of BPP scores.

Mitigation Strategy

Implement structured documentation templates and regular audits.

Documentation errors, coding pitfalls, and audit risks are interconnected aspects of medical coding and billing. Addressing all three areas helps ensure accurate coding, optimal reimbursement, and regulatory compliance.

Frequently Asked Questions

Common questions about ICD-10 coding for Biophysical Profile 4/8, with expert answers to help guide accurate code selection and documentation.

Documentation Templates for Biophysical Profile 4/8

Use these documentation templates to ensure complete and accurate documentation for Biophysical Profile 4/8. These templates include all required elements for proper coding and billing.

BPP 4/8 with absent fetal breathing

Specialty: Obstetrics

Required Elements

  • Fetal breathing movements
  • Gross body movements
  • Fetal tone
  • Amniotic fluid volume

Example Documentation

BPP score 4/8: 0 points for fetal breathing, 2 points for gross movements, 0 points for tone, 2 points for amniotic fluid.

Examples: Poor vs. Good Documentation

Poor Documentation Example
BPP 4/8, abnormal result.
Good Documentation Example
BPP score 4/8: 0 points for fetal breathing movements ≥30 sec, 2 points for ≥3 gross body movements, 0 points for absent fetal tone, 2 points for amniotic fluid pocket 3.2 cm.
Explanation
The good example provides detailed scoring for each BPP component, ensuring comprehensive documentation.

Need help with ICD-10 coding for Biophysical Profile 4/8? Ask your questions below.

Ask about any ICD-10 CM code, or paste a medical note

We build tools for
clinician happiness.

Learn More at Freed.ai
Back to HomeBeta

Built by Freed

Try Freed for free for 7 days.

Learn more